Atelier Kanu / Research
What our buildings teach us
We leave temperature loggers in finished buildings and publish what they record. Some findings confirm the drawings; a few have changed how we draw.
A March day in the Katampe house
Katampe courtyard houseOn 14 March outside air reached 37°C at two in the afternoon. In the living room, with windows open and no cooling, the air peaked at 29°C two hours later, and the floor stayed below 27°C all day.
The delay matters as much as the difference. By the time the room is warmest the sun is low behind the west screens and the evening breeze has begun.
Example data for this demo, drawn from a logger placed 1.2 m above the floor.
Current studies
- Screen spacingTwelve fin spacings tested on a west wall mock-up in our garden. Below 500 mm apart the glass stays in shade after 2pm in every month. Wider spacing saves clay but loses the March afternoons.
- Laterite blocksCompressed earth blocks from four Abuja sites, stabilised with 6 to 8% cement, tested for strength and water. Results feed our block specification.
- Roof gapsHow high a floating roof needs to sit. Above 450 mm the gain is small; below 300 mm the ceiling warms by up to 4°C in still weather.
- Harmattan dustWindow seals, deep reveals and planted edges, measured with dust trays over two dry seasons.
The garden lab
Materials libraryBehind the studio we keep a small test yard: wall panels of different builds facing west, a roof mock-up with an adjustable gap and a row of block samples left to the rain. It costs little and answers questions that software alone cannot.
Clients are welcome to visit during open studio and see their own wall samples weathering before they commit.
What we have published
JournalNotes on floating roofs
Six years of measurements under four roof types in Abuja, with drawings anyone may use.
A laterite block guide
How to test, stabilise, make and lay earth blocks on a domestic site, in plain language.
Shade in numbers
Sun angles for twelve Nigerian cities, by month and orientation, for architects and builders.
Example publications for this demo.
Questions about our research
Can we have loggers in our house?
Yes. We fit them at handover with your permission, retrieve the data twice a year and send you a short report. They record temperature and humidity only.
Do you share data that shows a building underperforming?
We do. Two of our early houses ran warmer than predicted in their first year; we changed the screens on one and our fin spacing rules for every project after it.